SolarSizer

MPPT and PWM charge controller specs

Built by Jeremy Panasuk. Published October 6, 2026.

Last reviewed: Oct 6, 2026 · Next review planned: January 2027

Each row is a model line from a manufacturer datasheet: maximum PV open-circuit voltage, the charge current that sheet prints, and the battery voltage. Cells quote the sheet. Nothing here is estimated.

Use the table after the charge controller tab prints a current. The tab does array watts ÷ battery volts ÷ 0.85, then picks the next size in 10, 20, 30, 40, 60, 80, and 100 A. That list is this site's rounding. It is not a model name in the table.

Worked example: 2,400 Wh at 4 sun hours is 2,400 ÷ 4 ÷ 0.86 = 697.67 W, which sizeSystem prints as 700 W. sizeController then does 700 ÷ 12 ÷ 0.85 = 68.6 A and lists 80 A. On this table the SmartSolar MPPT 100/50 row is 50 A, which is below 68.6 A. The SmartSolar MPPT 150/70 row is 70 A. The 150/70 voltage cell is 150 V absolute maximum in the coldest conditions and 145 V start-up and operating maximum. Current and open-circuit voltage are separate limits. The same walk-through is on how to size a solar charge controller.

The figures were copied from the linked datasheets on October 6, 2026. Every row has a source link. Download CSV (same rows).

Click a column heading to sort. The table does not move until you click.

Manufacturer Model Type Max. PV open-circuit voltage Charge current Datasheet name for that current Battery voltage Source
Victron EnergySmartSolar MPPT 75/10MPPT75 V10 ARated charge current12/24 VSmartSolar MPPT 75/10, 75/15, 100/15, 100/20-48V datasheet
Victron EnergySmartSolar MPPT 75/15MPPT75 V15 ARated charge current12/24 VSmartSolar MPPT 75/10, 75/15, 100/15, 100/20-48V datasheet
Victron EnergySmartSolar MPPT 100/15MPPT100 V15 ARated charge current12/24 VSmartSolar MPPT 75/10, 75/15, 100/15, 100/20-48V datasheet
Victron EnergySmartSolar MPPT 100/20-48VMPPT100 V20 ARated charge current12/24/48 VSmartSolar MPPT 75/10, 75/15, 100/15, 100/20-48V datasheet
Victron EnergySmartSolar MPPT 100/30MPPT100 V30 ARated charge current12/24 V Auto SelectSmartSolar MPPT 100/30 and 100/50 datasheet
Victron EnergySmartSolar MPPT 100/50MPPT100 V50 ARated charge current12/24 V Auto SelectSmartSolar MPPT 100/30 and 100/50 datasheet
Victron EnergySmartSolar MPPT 150/35MPPT150 V absolute maximum coldest conditions; 145 V start-up and operating maximum35 ARated charge current12 / 24 / 48 V Auto Select (software tool needed to select 36 V)SmartSolar MPPT 150/35 and 150/45 datasheet
Victron EnergySmartSolar MPPT 150/45MPPT150 V absolute maximum coldest conditions; 145 V start-up and operating maximum45 ARated charge current12 / 24 / 48 V Auto Select (software tool needed to select 36 V)SmartSolar MPPT 150/35 and 150/45 datasheet
Victron EnergySmartSolar MPPT 150/60MPPT150 V absolute maximum coldest conditions; 145 V start-up and operating maximum60 ARated charge current12 / 24 / 48 V Auto Select (software tool needed to select 36 V)SmartSolar MPPT 150/60 and 150/70 datasheet
Victron EnergySmartSolar MPPT 150/70MPPT150 V absolute maximum coldest conditions; 145 V start-up and operating maximum70 ARated charge current12 / 24 / 48 V Auto Select (software tool needed to select 36 V)SmartSolar MPPT 150/60 and 150/70 datasheet
Victron EnergySmartSolar MPPT 250/60MPPT250 V absolute maximum coldest conditions; 245 V start-up and operating maximum60 ARated charge current12 / 24 / 48 V Auto Select (software tool needed to select 36 V)SmartSolar MPPT 250/60 and 250/70 datasheet
Victron EnergySmartSolar MPPT 250/70MPPT250 V absolute maximum coldest conditions; 245 V start-up and operating maximum70 ARated charge current12 / 24 / 48 V Auto Select (software tool needed to select 36 V)SmartSolar MPPT 250/60 and 250/70 datasheet
MorningstarSS-MPPT-15LMPPT60 volts (without damage to unit)15 ampsMax. battery charging current12 or 24 voltsSunSaver MPPT datasheet
MorningstarPS-MPPT-25, PS-MPPT-25MMPPT120 Volts (without damage to unit)25 AmpsMax. Battery Current12V or 24VProStar MPPT datasheet
MorningstarPS-MPPT-40, PS-MPPT-40MMPPT120 Volts (without damage to unit)40 AmpsMax. Battery Current12V or 24VProStar MPPT datasheet
MorningstarTS-MPPT-30MPPT150 volts DC (without damage to unit)30 ampsMaximum Battery Current12, 24, or 48 volts DCTriStar MPPT datasheet
MorningstarTS-MPPT-45MPPT150 volts DC (without damage to unit)45 ampsMaximum Battery Current12, 24, or 48 volts DCTriStar MPPT datasheet
MorningstarTS-MPPT-60MPPT150 volts DC (without damage to unit)60 ampsMaximum Battery Current12, 24, or 48 volts DCTriStar MPPT datasheet
MorningstarTS-MPPT-60MMPPT150 volts DC (without damage to unit)60 ampsMaximum Battery Current (same cell as TS-MPPT-60)12, 24, or 48 volts DCTriStar MPPT datasheet
MorningstarPS-15, PS-15MPWM12V bat: 30Voc / 24V bat: 60Voc15AMaximum Battery Current (versions line: 15 amps)12V or 24VProStar datasheet
MorningstarPS-30, PS-30MPWM12V bat: 30Voc / 24V bat: 60Voc30AMaximum Battery Current (versions line: 30 amps)12V or 24VProStar datasheet
MorningstarSS-6/6LPWM30V6.5AMax. solar current12VSunSaver datasheet
MorningstarSS-10/10LPWM30V or 60V10AMax. solar current12V or 24VSunSaver datasheet
MorningstarSS-20LPWM30V or 60V20AMax. solar current12V or 24VSunSaver datasheet

ProStar PWM rows use the line labeled Max. PV Open Circuit Voltage (12V bat: 30Voc / 24V bat: 60Voc). The same datasheet also lists Maximum Solar Input Voltage as 12V/24V bat: 60Voc. SunSaver rows use the ratings table's "Max. solar voltage" and "Max. solar current". The SunSaver sheet calls the charging method 4 stage series PWM. Victron rows that print two PV-voltage limits include both. TS-MPPT-60 and TS-MPPT-60M share one 60 amp cell on the TriStar sheet.

What this table leaves out

Nominal PV power, maximum PV short-circuit current, and charge voltages are on several of these sheets and are not columns here. Every row above has a published figure for open-circuit voltage, charge current, and battery voltage.

The compilation on this page is published under CC BY 4.0. The datasheets linked in the table stay the manufacturers' documents.

Compiled with AI assistance from the sources below. Spot an error? Email [email protected].

Sources

Changelog

Oct 6, 2026: first published, 24 rows from 10 source documents.

← Back to the solar size calculator